In part one dan goes indepth about the data and information required to create milstd labels and the difference between the contruct1 and construct2 options. Introduction 28v defense applications must meet a number of noise and power related standards such as mil std 461, mil std 704, and mil std 1275. The latest version of mil std, version n, was released on december 17th, 2007. This issue of mil std continues to provide evolving clarification, increased insight, guidance, and marking criteria regarding implementation of machinereadable information. Give us the mil std 2073 codes from your contract and well get back to you with a free report. Construct 1 versus construct 2 a2b tracking solutions.
Since many contractors, and their subcontractors, have to mark many of the items they make to meet this standard, we thought it would be useful to produce a brief summary of the changes. Typically, a construct 1 format is used to mark gfp, or government furnished property. Both constructs are viable options for encoding the uid however this post will act as a recap of the two approaches to mil std and uid encoding. Nov 12, 2015 the standard practice involved in milstd has undergone some revisions, including milstdn, which was released in december 2007 and milstdn w change 1, which was released in november 2012.
Mil std n, which is made up of numerous other governmental and nongovernmental specifications, standards, publications, and handbooks, is meant to be used as a guide in which to. Walk through how to buy a uid label to pick material, size, fastening method, barcodes and data. Permanent, durable iuid labels for milstd compliance. To faclitate lnceroperability among users of rpf data, this standard specifies requirements for the integration of rpy files. Robert pauplis senior principal product line engineer. Listed below are the revisions which have referenced quality standards for bar codes and how each revision pertains to bar code quality testing. Milstd461g is in a draft state as of march 2015, adding the electrostatic discharge testing section of conducted susceptibility hereon referred to as cs118. Now that almost 8 years have passed, the practicality and direct experience involved in part marking has pushed construct 1 directly into the planning psyche. This military standard is approved for use by all departments and agencies of the department of defense. Jeffrey ham principal product line engineer contributions by. Milstd461g cs118 personnel borne electrostatic discharge esd notice. Milstd labels using construct 1 or construct 2 a2b. This tutorial focuses specifically on generating the barcode according to mil std n. Comments, suggestions, or questions on this document should be addressed to.
There are two major dialects of formatting known as format 06, and format 12. Military property this standard provides the item marking criteria for development of specific marking requirements and methods for identification of items of military property produced, stocked, stored, and issued by or for the department of defense dod. Well interpret your 2073 codes you need answers now. When combining marking requirements with mil std 129, the manner, method, form, and format of mil std 129 mri and hri requirements shall be followed and the informational requirements of this standard. Western distribution center french camp, ca eastern distribution center burlington, nj. Jan 18, 2020 the following information is by no means exhaustive but meant to provide a basic understanding and general overview of milstd. This tutorial uses the gs1 2d data matrix symbol in fig. Approved for public release, distribution is unlimited.
There are several types of uid marking labels that may be created within the mil std specification. Learn about specifications, markings and requirements for military standard read more. The latest revision of mil std as of september 2019 is mil std n wchange 1 dated 16 november 2012, superseding mil std n dated 17 december 2007. This change establishes direct and specific reference to the governing iuid policy, regulation and whats included in the milstdn. Additional information can be found in the dod uid guide.
Detrimental materials analysis milstd2041 test method. This standard is approved for use by all departments and agencies of the department of defense. Uii type where serial number is unique within the enterprise. Dec 02, 2005 mil std m 2 december 2005 superseding mil std l wchange 1 20 december 2004 department of defense standard practice identification marking of u.
Its a question we get a lot when being asking for 2d data matrix codes to be marked or engraved into a product. This page was last edited by bob goeke on 16 april 2015 there have been 322814 accesses to this page since 11520. Beneficial comments recommendations, additions, deletions and any pertinent data which. Fed std 123 applies when orders are shipped to gsa supply centers, such as. Enhance your product appearance with attractive and. With gsa contracts now shipping both to gsa and dla locations, compliance with two different standards is required.
Milstd461g cs118 personnel borne electrostatic discharge esd. This standard provides the item marking criteria for development of specific marking requirements and methods for identification of items of military property produced, stocked, stored, and issued by or for the department of defense. The dod requires that contractors include a two dimensional 2d data matrix bar code on their shipping labels. If youre trying to figure out mil std 2073 this compliance guide will help you get up to speed. This standard covers the methods, materials, and techniques to be employed in the formation. Military property, milstd provides directions as to how to mark items sold to the department of defense dod. Milstd versions the military standard is the united states department of defenses standard practices for uniquely identifying military property. Us department of defense mil std the mil std is used by the us department of defense dod in the implementation of machine readable information for item identification marking and automatic data capture. Barcode scanning and iuid verification fixed station 2d data matrix verification systems. The latest revision of milstd as of september 2019 is mil std n wchange 1 dated 16 november 2012, superseding mil std n dated 17 december 2007. Laser marking for unique identification industrial laser solutions. This standard provides uniform marking requirements for electronic items. Using the construct 2 you have not only your cage code and your serial number, but you also have the part number which makes up the iuid. Kapton polyimide uid labels for mil std and stanag 2290 compliance when your contract specifies polyimide labels the choice for superior performance and durability.
Uid labels are manufactured from the approved proof. This standard is approved for use by all departments and agencies of the department of defense dod. Milstdn, which is made up of numerous other governmental and. To complete your mil std compliance, we submit your uiis to the iuid registry in 48 hours. Milstd labels using construct 1 or construct 2 a2b tracking. Apr 25, 2017 in part one dan goes indepth about the data and information required to create mil std labels and the difference between the contruct1 and construct 2 options. Below is an overview to help you better understand the change to this standard. And the construct 2 format is used for new acquisition or enditems. Department of defense dod issued a change to milstd.
Detrimental materials analysis milstd2041 test method the purpose of this standard is to establish uniform requirements for control of detrimental materials in products and equipment that come in contact with special purpose hardware. If an item is serialized within the part number, a construct 2 syntax that includes. Milstd461g cs118 is a brand new core requirement for milstd461 testing. Fixed station 2d data matrix iuid verification systems help to ensure that manufacturers and contractors producing equipment for the united states department of defense dod meet standards outlined in the mil std specification. Published on november 16, 2012, milstd n change 1 is the latest version of the standard. This standard is approved for use by the naval sea systems command, department of the navy, and is available for use by all departments and agencies of the department of defense. This standard provides uniform marking requirements for electrical and electronic parts.
This issue of mil std continues to provide evolving clarification, increased insight and. If you would like to learn more about staying compliant to the mil std requirements watch the ondemand recording of our recent webinar here. Mil std 810, environmental engineering considerations and laboratory tests, is a united states military standard that emphasizes tailoring an equipments environmental design and test limits to the conditions that it will experience throughout its service life, and establishing chamber test methods that replicate the effects of environments on the equipment rather than imitating the. Milstd n department of defense standard practice identification of. Gsa requires milstd129 and fedstd123 milpac technology. This issue of milstd provides further clarification and increased insight and guidance. Reference our barcode guide and barcode glossary for guidance on barcode symbologies. Abstract cabin electronic equipment can be effected by electrostatic discharge due to environmental and installation conditions, such as low relative humidity and the use of poor or nonconductive materials for carpets, seat textiles, arm rests, etc.
Mil standard 461 g final release december 11th, 2015. Us department of defense milstd tharo systems, inc. Milstd2073 for military packaging codes easysoft corp. The construction rules depend upon the serial number being unique to that part.